The four other hb estimation methods were tested against the hemocue hb 301 system. Providing results closely correlated with a reference lab method, the hemocue glucose 201 system is cleared for supplementing the clinical evidence in the diagnosing of diabetes. Operating manual bedienungsanleitung manuel dutilisation. Hemocue hb 201 data management system engineering for change. The hemocue hb 201 dm system offers lab accuracy and ease of use, plus improved patient safety with features like qc lockout and builtin barcode scanning for patient id. This manual was produced by the who steps geneva team. The hemocue hb 201 dm system is a data management solution for hemoglobin testing and anemia screening. This operating manual provides the basic instructions for routine use as well as technical specifications. Make sure the control is mixed properly and at room. Page 3 capillary, venous or arterial whole blood may be used. Plus, you have the added controls and productivity. Hemocue b4 received a complaint on hemocue glucose 201 dm from hemocue b6. Many clinicians may be unaware of many glucose strip meters being cleared only for use on known diabetics. Clean side arm self test performed high control low control tech initials range.
Page 11 quality control testing internal electronic quality control eqc the hemocue hb 201 dm analyzer has an internal electronic quality control performed when analyzer displays selftesting every time the analyzer is turned on, it will automatically verify the performance of the optronic unit during the selftesting. It is ideally suited for health care facilities that require central lab quality values within a few minutes, at the point of care location. Hemocue glucose 201 dm system measures blood glucose levels to. Uni can anyone share how nus dentistry manual dexterity. Have good manual dexterity skills during various work experience roles and through degree studies. In vitro principle of the method principle of the procedure. The hemocue glucose 201 dm sends results to host system by using the clsi poct1a communication.
Justine mathew thomas research associate astrazenca. Hemocue glucose 201 dm system in diabetes diagnostics, the hemocue glucose 201 dm system is used to measure blood glucose levels. With its unique cuvette technology, the hemocue glucose 201 dm system gives you accuracy at the point of care. Hemocue 201 dm mmoll 0 0 5 10 15 20 25 5 10 15 20 25 hemocue glucose 201 dm vs vista 1500, individual replicates. Blood glucose test data management hemocue glucose 201 dm. Ogtt is more sensitive for diagnosing diabetes and impaired glucose tolerance but is less convenient. The hemocue hb 201 dm system is a compact, portable, yet versatile, hemoglobin measuring system. The hemocue hb 201 dm system provides labquality hemoglobin results at the pointofcare by means of a wide range of settings and definable options, the system can be made to prompt the operator for identification, lot numbers, quality control and other required information during analysis. Capillary, venous or arterial whole blood may be used. For installation, setup and other vital information, consult the hemocue hb 201 dm reference manual. The hemocue hb 201 dm system consists of a photometer analyzer with specially designed microcuvettes containing dry. Blood glucose test data management hemocue glucose 201. The controls are beyond their expiration dates or have been improperly stored 8.
With its unique cuvette technology, the hemocue glucose 201 dm rt system gives you the highest accuracy at the point of care. Every time the analyzer is turned on, it will automatically verify the performance of the optronic unit of the analyzer. Should it be determined that a handheld device for field blood che analysis would be. Whether a rehabilitation practitioner, a medical researcher or a human resources professional, the minnesota dexterity test is a great choice for providing valuable information about a subjects dexterity. If additional quality control testing is required for regulatory reasons, contact hemocue, inc. The hemocue glucose 201 dm analyzer offers features like qc lockout and built in barcode scanning for patient id. Hemocue hb 201 plus operating manual pdf download manualslib. This manual provides the basic instructions for use as well as technical specifications. Not available in the us, for corresponding us product see. Pdf evaluation of the relationship between capillary and venous. The dm hemocue analyzer will accurately read hemoglobin results. Through bidirectional communication and flexible settings, the system offers a complete data management solution for glucose testing. The disposable microcuvette is made of plastic and comprises a body ha the cuvette cavity contains reagents deposited on its inner walls and the. Simple test of manual dexterity can help to identify persons.
The minnesota manual dexterity test offers diverse testing options making it one of the most diverse dexterity testing devices available. Who library cataloguinginpublication data who world health. This manual contains stepbystep instructions for the routine use of the hemocue hb 201 dm analyzer. Since capillary blood samples are easier to obtain and require less.
The hemocue 201 dm system is a compact, portable, yet versatile, measuring system. Hemocue hb 201 dm system support patient safety and simplified workflow hemocue s hb 201 dm system offers the lab accuracy and ease of use that has become a standard in hb pointofcare testing, with features like qc lockout and builtin barcode scanning for patient id to support patient safety and privacy. Type 1 insulindependent diabetes mellitus presenting in neonates is rare and. It is a way to manage patient information as it has qc lockout and barcode scanning for patient id. Through bidirectional communication and flexible settings, the system offers a complete data management solution for hb testing and anemia screenin.
Improve your administrative workflow seamlessly interface with existing network using poct1a. An evaluation of blood cholinesterase testing methods for. Summary the hemocue glucose 201 rt systems are based on a glucose dehydrogenase method and consist of a small dedicated analyzer and a unique disposable microcuvette. Pdf comparative evaluation of haemoglobin estimation amongst. The results can be printed directly via an external printer or downloaded to a pc. As the pioneer of labquality, cliawaived hemoglobin testing, weve built a global business around this simple yet important assay. Through bidirectional communication and flexible settings, the hemocue hb 201 dm system offers a complete data management solution for hb testing and anemia screening in blood banks, hospitals, primary care and public health. Check the expiration date and the storage conditions of the microcuvettes.
This test is performed every second hour if the analyzer remains switched on. Through bidirectional communication and flexible settings, the system offers a complete data management solution for hb testing and anemia screening at the pointofcare. For patient testing, prepare analyzer before proceeding with steps 15. Measurement after an 8 to 12hour fast fpg or 2 hours after ingestion of a concentrated glucose solution oral glucose tolerance testing ogtt is best see table diagnostic criteria for diabetes mellitus and impaired glucose regulation. The hemocue system can be linked with existing systems using poct1a point of care testing standards. It is ideally suited for health care facilities that require central lab quality values within a. It will therefore effectively clean the optical lens by absorbing the blood without smearing it. The hemocue glucose 201 system is an analyzer, not a meter. An oral glucose tolerance test ogtt is the standard of choice to diagnose diabetes mellitus. The system consists of the hemocue hb 201 dm analyzer, the hemocue dm docking station, the hemocue hb 201 microcuvettes. Uni can anyone share how nus dentistry manual dexterity test mdt and interview works. Hemoglobin test data management hemocue hb 210 dm system. From specimen collection to rapid tests kits to analyzers, clia waived or highly complex.
Available for both hemoglobin and glucose testing, they offer healthcare providers faster data availability, better quality control, increased regulatory compliance and improved administration. The hemocue hemoglobin test is used for the screening and ongoing. Rapid quantitative measurement of hemoglobin concentration in peripheral blood at the point of care. The calibration of the analyser has been changed 1. To learn more about hemocue glucose 201 dm, please scan the. The hemocue glucose 201 dm system was reported to have presented a single low measurement result that was compared to a laboratory result. Manufacturer narrative hemocue glucose 201 dm measured 3. Blood cholinesterase che testing is done to evaluate potential human exposure to chemicals that act.
Station has been described in hemocue 201 dm docking station manual. Being light and portable, as well as having a mains power option, the hemocue hb 201 system is equally suited for both static and mobile use. Please read the relevant operating manual for proper use of the system1. Islh 2017 abstract proceedings wiley online library. Diabetes mellitus dm endocrine and metabolic disorders. The reagentsmicrocuvettes and the analyzer form an analytical system. University hi, im a bit confused as to how the mdt and interview is done this year with the covid19 around. Healthcare providers around the world rely on the immediate results so they can make the right decisions when they need them most right at the point of care. Performance report hemocue glucose 201 rt systems this document summarizes the performance of the hemocue glucose 201 rt system and the hemocue glucose 201 dm rt system. For patient testing, prepare analyzer before proceeding.
This reference manual contains instructions for settings, quality assessment, patient testing, and troubleshooting of the hemocue hb 201 dm analyzer, as. Page 1 hemocue hb 201 operating manual bedienungsanleitung manuel dutilisation gebruiksaanwijzing. The hemocue hb 201 dm system brings your practice labquality hemoglobin results at the pointofcare, with added controls and advanced data management capabilities, including qc lockout and builtin barcode scanning to support data integrity and privacy, along with bidirectional communication and flexible settings. The rationale and use of coordinated improvement of laboratory testing and. With data management you gain higher efficiency in everything from patient management to billing. Intended purposeintended use quantitative determination of hemoglobin in capillary, venous and arterial whole blood, using a specially designed analyzer, the hemocue hb 201 analyzer, and spe. Plus, you have the added controls and productivity means made possible with advanced data management.
158 420 608 1224 1020 1217 1517 1293 988 1084 187 136 182 287 1605 214 983 1076 362 862 1246 807 968 51 429 1123 1471 963